5.2.10 9-** PROFIdrive
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
9-00
Setpoint
0 N/A
All set-ups
TRUE
0
Uint16
9-07
Actual Value
0 N/A
All set-ups
FALSE
0
Uint16
9-15
PCD Write Configuration
ExpressionLimit
1 set-up
TRUE
-
Uint16
9-16
PCD Read Configuration
ExpressionLimit
1 set-up
TRUE
-
Uint16
9-18
Node Address
126 N/A
1 set-up
TRUE
0
Uint8
9-19
Drive Unit System Number
1037 N/A
All set-ups
TRUE
0
Uint16
9-22
Telegram Selection
[100] None
1 set-up
TRUE
-
Uint8
9-23
Parameters for Signals
0
All set-ups
TRUE
-
Uint16
9-27
Parameter Edit
[1] Enabled
1 set-up
FALSE
-
Uint16
9-28
Process Control
[1] Enable cyclic
master
1 set-up
FALSE
-
Uint8
9-44
Fault Message Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-45
Fault Code
0 N/A
All set-ups
TRUE
0
Uint16
9-47
Fault Number
0 N/A
All set-ups
TRUE
0
Uint16
9-52
Fault Situation Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-53
Profibus Warning Word
0 N/A
All set-ups
TRUE
0
V2
9-63
Actual Baud Rate
[255] No baudrate
found
All set-ups
TRUE
-
Uint8
9-64
Device Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-65
Profile Number
0 N/A
All set-ups
TRUE
0
OctStr[2]
9-67
Control Word 1
0 N/A
All set-ups
TRUE
0
V2
9-68
Status Word 1
0 N/A
All set-ups
TRUE
0
V2
9-70
Edit Set-up
[9] Active Set-up
1 set-up
TRUE
-
Uint8
9-71
Profibus Save Data Values
[0] Off
All set-ups
TRUE
-
Uint8
9-72
ProfibusDriveReset
[0] No action
1 set-up
FALSE
-
Uint8
9-75
DO Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-80
Defined Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-81
Defined Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-82
Defined Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-83
Defined Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-84
Defined Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-85
Defined Parameters (6)
0 N/A
All set-ups
FALSE
0
Uint16
9-90
Changed Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-91
Changed Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-92
Changed Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-93
Changed Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-94
Changed Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-99
Profibus Revision Counter
0 N/A
All set-ups
TRUE
0
Uint16
5.2.11 10-** CAN Fieldbus
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
10-0* Common Settings
10-01 Baud Rate Select
[20] 125 Kbps
1 set-up
TRUE
-
Uint8
10-02 Node ID
127 N/A
1 set-up
TRUE
0
Uint8
10-05 Readout Transmit Error Counter
0 N/A
All set-ups
TRUE
0
Uint8
10-06 Readout Receive Error Counter
0 N/A
All set-ups
TRUE
0
Uint8
10-3* Parameter Access
10-31 Store Data Values
[0] Off
All set-ups
TRUE
-
uint8
Parameter Lists
VLT
®
Midi Drive FC 280
124