Command
Syntax Parameters Description
calcu late cam era gain
ccg
i t i
Calcu lates the cam era gain and op tim izes
tap m atching accord ing to the selected
algorithm .
i
= Calibration algorithm to u se.
1
= This algorithm ad ju sts analog
gain so that 8% to 13% of tap ROI
p ixels are above the sp ecified target
valu e.
2
= This algorithm ad ju sts analog
gain so that the average p ixel valu e
in tap’s ROI is equal to the specified
target valu e.
3
= This algorithm ad ju sts d igital
gain so that the average p ixel valu e
in tap’s ROI is equal to the specified
target.
4
=
This algorithm ad ju sts the analog
gain so that all tap ROI p ixels are
w ithin 98% of the sp ecified target
valu e and then p erform s a PRN U
correction.
t =
Tap valu e. Use
0
for all tap s or
1
to
8
for ind ivid u al tap selection.
i
= Calibration target valu e in a range
from
1024
to
4055
DN (12 bit LSB).
correction calibrate p rnu
ccp
Start PRN U coefficient calibration. Refer
to section 3.4.2 Analog and Digital Signal
Processing Chain for d etails.
cam era link m od e
clm
i
Sets the Cam era Link configu ration,
nu m ber of Cam era Link tap s, and d ata
bit d ep th.
15
: Med iu m configu ration, 4 tap s, 8 bit
ou tp u t
16
: Med iu m configu ration, 4 tap s, 12 bit
ou tp u t
21
: Fu ll configu ration, 8 tap s, 8 bit
ou tp u t
Refer to section 3.3.1 Setting the Cam era
Link Mod e for d etails.