Piranha 3 User Manual
03-032-10216-06
Teledyne DALSA
30
Mode 7: Internally Programmable Line Rate, Maximum Exposure Time
In this m od e, the line rate is set internally w ith a m axim u m exp osu re tim e.
Figure 11: Mode 7 Camera Timing
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this m od e, the exp osu re tim e is set internally w ith a m axim u m line rate.
Figure 12: Mode 8 Timing
Programmable Period
Frame Period
Readout
CR Exposure Time
CR=Charge Reset
Frame Period
Programmable Period
CR Exposure Time
Readout
Setting the Line Rate
Pu rp ose:
Sets the camera’s line rate in Hz. Camera must be operating in
exp osu re m od e 2 or 7.
Syntax:
ssf
f
Syntax Elem ents:
i
Desired line rate in H z. Allow able valu es are:
12k:
2500-23619
H z
8k:
2500-33855
H z
N otes:
To read the cu rrent line frequ ency , u se the com m and
gcp
or
get
ssf
.
If you enter an invalid line rate frequ ency, an error m essage is
retu rned .
Related Com m and s:
sem
,
set
Exam p le:
ssf 10000
Exposure Time
Readout
Internal Sync set
with Command
ssf
Line Period
Exposure Time
Readout
Line Period
EXSYNC Falling
Edge ignored
EXSYNC Falling
Edge ignored
during readout
i
Applies to Modes 2 and
7
during readout
(Only Possible on
sot
change)