Piranha 3 User Manual
Teledyne DALSA
03-032-10216-06
41
The follow ing d iagram s su m m arize and p rovid e an exam p le of how analog gain is
calibrated w hen u sing a region of interest.
In the follow ing exam p le, analog gain is being set for a single tap insid e the region of
interest. The p eak valu e of the tap is calibrated to the sp ecified target valu e and all other
tap s rem ain u nchanged .
Figure 14: Calibrating Analog Gain for a Tap outside of the Region of Interest
Tap 1(odd)
Tap 2(even)
Video
Region of Interest
ccg 1 4 2800
Since tap 4 is within the region of interest,
tap 4 gain is adjusted so that the peak value
is set to 2800. Gain values for all other taps are
left unchanged.
Tap 5(odd)
Tap 6(even)
Tap 7(odd)
Tap 8(even)
V
id
e
o
0
12288
4000
9700
2800
0
4095
Pixel Number
After analog gain calibration
Before analog gain calibration
Tap 4(even)
Tap 3(odd)
All manuals and user guides at all-guides.com
all-guides.com