background image

Diesel

DEF

Chemicals

Submersible Level Sensors

200C Series

Operating Manual

Continuous Submersible Level Transmitter

200C Series 

(Capacitive Ceramic)

R

www.iconprocon.com | [email protected] | 905.469.9283

R

Summary of Contents for Level pro 200C Series

Page 1: ...esel DEF Chemicals Submersible Level Sensors 200C Series Operating Manual Continuous Submersible Level Transmitter 200C Series Capacitive Ceramic R www iconprocon com sales iconprocon com 905 469 9283...

Page 2: ...y Connection Diagram Sensor TVL Display Connection Diagram Sensor Sentinel LTE TVL Display Understanding Level Measurement Application Details Getting Started Calculating Max Range of Sensor Correctio...

Page 3: ...issued to our best knowledge Levelpro is not liable for any incorrect statements and their effects www iconprocon com sales iconprocon com 905 469 9283 03 Continuous Submersible Level Transmitter 200C...

Page 4: ...the probe has to be submerged slowly into the medium A rough immersion into the medium can damage or destroy the diaphragm If there is any danger of damage by lightning or overpressure when the device...

Page 5: ...g Temperatures PVC 32 F 140 F PP 20 F 178 F PVDF 40 F 212 F PTFE 40 F 212 F Electrical Protection Short Circuit Protection Reverse Polarity Protection Permanent No Damage to Sensor Electromagnetic Com...

Page 6: ...inuous Submersible Level Transmitter 200C Series Capacitive Ceramic R Before After Features New Vaporbloc Technology NEMA 4X Enclosure Tool Free Wiring Terminals All Plastic NEMA 4X Enclosure 2 Thread...

Page 7: ...or Adjustable Relay Timer NEMA 4X Enclosure LED Display All Plastic Corrosion Resistant All Cord Grips Included Simple Programming Features SunBright Technology for Outdoor Applications No Assembly Re...

Page 8: ...ble Gland Remove Heat Shrink Discard Heat Shrink Remove Filter from Vent Tube Feed Wires through VaporBloc Ensure VaporBloc is Oriented Correctly Sensor Junction Box Installation www iconprocon com sa...

Page 9: ...talled Take Junction Box Open Lid Open Lid Fuming Liquids Please Install VaporBloc 1 Feed Sensor Red and Black Wire Breather into Junction Box 2 Tighten Cord Grip 1 4 Turn Lid is Tethered Do Not Bend...

Page 10: ...nd Tighten Only Connection Diagram Sensor 250B Display 200C Series Level Sensor Supply Supply Vs Red Black Sensor Wire Red Terminal 1 Black Terminal 3 Red Terminal 2 Black Terminal 4 200C Series Senso...

Page 11: ...tput Examples Pump Shut Off Valve Shut Off Wiring to a Loop Powered Display 200C Series Level Sensors 1 2 3 4 5 6 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Power Supply 120VAC Terminal 1 2 TVL Channel Te...

Page 12: ...6 Junction Box Terminals Green wire Terminal 5 Black wire Terminal 4 Junction Box Terminals Red wire Terminal 3 Black wire Terminal 2 13 12 11 10 09 08 07 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 2 wire sy...

Page 13: ...mpty 4mA setting 2 Full The Pressure being exerted on the sensor s diaphragm at the highest point Liquid Level within the Tank Full 20mA setting 3 Chemical Concentration Specific Gravity Temperature S...

Page 14: ...he submersible sensor range changes when submersed into liquids with different Specific Gravities Please note that the physical location of the level transmitter will indicate the lowest level of meas...

Page 15: ...be in the tank S G 0 5 34 5 64 feet or 816 inches Since the oil is a lighter fluid than H20 the new measuring range of the sensor has increased and is now 64 or 816 The liquid in Tank 2 has a S G 2 wh...

Page 16: ...a LP100 junction box located on top of the tank Since the vent tube is contained within the cable the pressure within the junction box A Gortex Breather to ensure accurate atmospheric pressure inside...

Page 17: ...ted with a Gortex Filter this must remain attached in order to prevent moisture particulate or insects from entering Do Not Remove Avoid blocking or bending the ventilation tube The LP100 Installation...

Page 18: ...ical or chemical damage due to improper accidental or negligent use 3 Have been modified or altered 4 Anyone other than service personnel authorized by Icon have attempted to repair 5 have been involv...

Page 19: ......

Reviews: