Piranha 3 User Manual
03-032-10216-06
Teledyne DALSA
80
Command
Syntax Parameters Description
get line average
gla
x1 x2
Read the average of line sam p les.
x1
= Pixel start nu m ber
x2
= Pixel end nu m ber
in a range from
1
to
sensor pixel
count
.
Refer to Retu rning Averaged Lines of
Vid eo on p age 45 for d etails.
get p rnu coeff
gpc
i
Read the PRN U coefficient.
i
= p ixel nu m ber to read in a range from
1 to sensor p ixel cou nt.
Refer to Retu rning Calibration Resu lts
and Errors on p age 49 for d etails.
get signal frequ ency
gsf
i
Read the cu rrent sync frequ ency.
1
: CC1 (EXSYN C)
2
: CC2 (PRIN )
3
: CC3 (Sp are)
4
: CC4 (Sp are)
Refer to section 3.6.5 Cam era Frequ ency
Measu rem ent for d etails.
get sensor serial
gss
Read the sensor serial nu m ber
help
h
Disp lay the online help . Refer to on p age
24 for d etails.
load p ixel coefficients
lpc
i
Load s the p reviou sly saved p ixel
coefficients from non -volatile m em ory
w here
i
is:
0
= Factory calibrated coefficients
1
= Coefficient set one
2
= Coefficient set tw o
3
= Coefficient set three
4
= Coefficient set fou r
Refer to 3.5.1 Saving and Restoring
PRN U and FPN Coefficients for d etails.
reset cam era
rc
Reset the entire cam era (reboot).
restore factory settings
rfs
Restore the camera’s factory settings.
FPN and PRN U coefficients reset to 0.
Refer to section 3.5 Saving and Restoring
Settings for d etails.
region of interest
roi
x1 y1 x2
y2
Sets the p ixel range affected by the cag,
cao, gl, gla, ccf, and ccp com m and s. The
p aram eters are the p ixel start and end
valu es (x) and the colu m n start and end
valu es (y) in a range from 1 to sensor
p ixel cou nt. Refer to section 3.4.1 Setting
a Region of Interest (ROI:setting) for
d etails.
reset p ixel coeffs
rpc
Reset the p ixel coefficients to 0. Refer to
Resetting the Cu rrent Pixel Coefficients
on p age 53 for d etails.
All manuals and user guides at all-guides.com