Command
Syntax Parameters Description
restore u ser settings
rus
Restore the cam era's last saved u ser
settings and FPN and PRN U coefficients.
Refer to section 3.5 Saving and Restoring
Settings for d etails.
set analog gain
sag
t f
Sets the analog offset.
t
= Tap valu e.
0
for all tap s or
1
-
8
for
ind ivid u al tap selection.
f
= gain valu e sp ecified from
–
10
to
+10
Refer to Analog Signal Processing:
Setting Analog Gain and Offset on p age
38 for d etails.
set analog offset
sao
t i
Sets the analog offset.
t
= Tap valu e.
0
for all tap s or
1
-
8
for
ind ivid u al tap selection.
i
= Offset valu e in a range from 0 to 255.
Offset increases w ith higher valu es.
Refer to Analog Signal Processing:
Setting Analog Gain and Offset on p age
38 for d etails.
set bau d rate
sbr
i
Set the sp eed of cam era serial
com m u nication p ort. Bau d rates:
9600
,
19200
,
57600
, and
115200
. Defau lt:
9600. Refer to section Setting Bau d Rate
on p age 24 for d etails.
set d igital offset
sdo
t i
Su btracts the inp u t valu e from the vid eo
signal p rior to FPN correction.
t
= Tap valu e.
0
for all tap s or
1
to
8
for
ind ivid u al tap selection.
i
= Offset in a range from
0
to
2048
DN .
Refer to
Setting Digital Offset on p age45 for
d etails.
set exp osu re m od e
sem
m
Set the exp osu re m od e:
2 =
Internal SYN C, internal PRIN ,
p rogram m able line rate and exp osu re
tim e u sing com m and s
ssf
and
set
3 =
External SYN C, internal PRIN ,
m axim u m exp osu re tim e
4
= Sm art EXSYN C
5
= External SYN C and PRIN
6
= External SYN C, internal PRIN ,
p rogram m able exp osu re tim e
7 =
Internal p rogram m able SYN C,
m axim u m exp osu re tim e. Factory
setting.
8
= Internal SYN C, internal PRIN ,
p rogram m able exp osu re tim e. Maxim u m
line rate for exp osu re tim e.
set exp osu re tim e
set
f
Sets the exp osu re tim e. Refer to the
cam era help screen (
h
com m and ) for
allow able range.
All manuals and user guides at all-guides.com