Piranha 3 User Manual
Teledyne DALSA
03-032-10216-06
29
Mode 4: Smart EXSYNC, External Line Rate and Exposure Time
In this m od e, EXSYN C sets both the line p er iod and the exp osu re tim e. The rising ed ge of
EXSYN C m arks the beginning of the exp osu re and the falling ed ge initiates read ou t.
Example 3: Trigger Period is Repetitive and Greater than Read Out Time.
Exposure Time
CR
Exposure Time
Readout
Line Period
Line Period
EXSYNC
CR
Readout
Mode 5: External Line Rate (EXSYNC) and External Pixel Reset (PRIN)
In this m od e, the falling ed ge of EXSYN C sets the line p eriod and the rising ed ge of PRIN
sets the start of exp osu re tim e.
Figure 9: EXSYNC controls Line Period and PRIN controls Exposure Time
Mode 6: External Line Rate and Internally Programmable Exposure Time
Figure 10: EXSYNC controls Line Period with Internally controlled Exposure Time
Readout
EXSYNC
Line Period
cr=Charge Reset
Readout
PRIN
Line Period
Line Period
Readout
EXSYNC
Line Period
CR=Charge Reset
Readout
Line Period
Programmable Period
Using Command
set
Programmable Period
Using command
set
All manuals and user guides at all-guides.com