Piranha 3 User Manual
Teledyne DALSA
03-032-10216-06
19
Medium and Full Configuration
Camera Connector Right Angle
Frame Grabber
Channel Link Signal Cable Name
9
18
Z1-
PAIR8-
22
5
Z1+
PAIR8+
10
17
Z2-
PAIR9+
23
4
Z2+
PAIR9-
11
16
Zclk-
PAIR10-
24
3
Zclk+
12
15
Z3-
25
2
Z3+
PAIR11-
13
13
inner shield
Inner Shield
26
26
inner shield
Inner Shield
Table 9: Camera Control Configuration
Signal
Configuration
CC1
EXSYN C
CC2
PRIN
CC3
Sp are
CC4
Sp are
Input Signals, Camera Link
The cam era accep ts control inp u ts throu gh the Cam era Link MDR26F connector.
The camera ships in internal sync, internal programmed integration (exposure mode 2).
EXSYNC (Triggers Line Readout)
Line rate can be set internally u sing the serial interface. The external control signal
EXSYN C is op tional and enabled throu gh the serial interface. This cam era u ses the
falling
edge of EXSYN C
to trigger line read ou t. Section 3.2.1 Exp osu re Mod e, Line Rate and
Exp osu re Tim e d etails how to set fram e tim es, exp osu re tim es, and cam era m od es.
Output Signals, Camera Link
These signals ind icate w hen d ata is valid , a llow ing you to clock the d ata from the cam era
to you r acqu isition system . These signals are p art of the Cam era Link configu ration and
you shou ld refer to the Cam era Link Im p lem entation Road Map , available
here
, for the
stand ard location of these signals.
Clocking Signal
Indicates
LVAL (high)
Ou tp u tting valid line
DVAL (high)
Valid d ata
STROBE (rising ed ge)
Valid d ata
FVAL (high)
Ou tp u tting valid fram e
• The camera internally digitizes 12 bits and outputs 8 MSB or all 12 bits depending on
the camera’s Camera Link operating mode. Refer to section 3.3.1 Setting the Camera
Link Mod e for d etails on setting the Cam era Link configu ration.
• For a Camera Link reference refer to Appendix A on page 71.
IMPORTANT:
This camera’s data
should be sampled on
the rising edge of
STROBE.
i