Presentia C v2 

 

 

 

 

 

Presence Detector with Luminosity Sensor  

for Ceiling Mounting 

 

 

 

 

 

 

 

 

ZPDC30LV2 

U

S

E

R

 M

A

N

U

A

L

 

 

 

 

 

 

Application program version: [1.2]  

User manual edition: [1.2]_a 

 

 

 

www.zennio.com

  

 

 

Summary of Contents for Presentia C v2

Page 1: ...Presentia C v2 Presence Detector with Luminosity Sensor for Ceiling Mounting ZPDC30LV2 USER MANUAL Application program version 1 2 User manual edition 1 2 _a www zennio com...

Page 2: ...port http support zennio com 2 CONTENTS Contents 2 1 Introduction 3 1 1 Presentia C v2 3 1 2 Installation 4 1 3 Start Up and Power Loss 5 2 Configuration 6 2 1 General 6 2 2 Presence Detector 8 2 3 Lo...

Page 3: ...e 4 sensors with configurable sensitivities 4 LEDs to indicate motion Presence detection 6 presence detection channels Luminosity dependent presence detection optional Periodic and delayed sendings bi...

Page 4: ...1 Presentia C v2 Elements The main elements of the device are described next Programming button 5 a short press on this button sets the device into the programming mode making the associated LED 2 lig...

Page 5: ...uring the start up of the device the Test Prog LED will blink in blue colour for one minute before the motion sensors are ready Depending on the configuration some specific actions will also be perfor...

Page 6: ...resence Detection enabled 1 enables the Presence Detector tab in the tree on the left For more information see section 2 2 Logic Functions enabled disabled enables or disables the Logic Functions tab...

Page 7: ...zennio com Technical Support http support zennio com 7 Note the first sending after download or bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sending...

Page 8: ...sts in sending KNX orders to the dimmer device that controls the in room luminaries so the ambient light level remains constant even if other light sources are present Occupancy detection is an algori...

Page 9: ...ion of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after executi...

Page 10: ...0 Disable 1 Enable 1 Bit I C W DPT_Enable 0 1 Detection LEDs 0 Disable 1 Enable Only During the Day 12 1 Byte O C T R DPT_Scaling 0 100 Occupancy Output Scaling 0 100 13 1 Byte O C T R DPT_HVACMode 1...

Page 11: ...I C W DPT_Enable 0 1 CLCx Lock Status 0 Lock 1 Unlock 87 103 1 Bit I C W DPT_Switch 0 1 CLCx Force State 0 No Detection 1 Detection 88 104 1 Bit I C W DPT_Switch 0 1 CLCx External Switch 0 No Detecti...

Page 12: ...4 195 196 197 2 Bytes I C W DPT_Value_2_Ucount 0 65535 LF 2 Byte Data Entry x 2 Byte Data Entry DPT_Value_2_Count 32768 32767 DPT_Value_Tempo 273 00 670760 00 198 199 200 201 202 203 204 205 4 Bytes I...

Page 13: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...