Returning PRNU Coefficients
Pu rp ose:
Returns a pixel’s PRNU coefficient value in DN (12 bit LSB)
Syntax:
gpc
i
Syntax Elem ents:
i
The p ixel nu m ber to read in a range from
1
to
sensor
pixel count
.
Exam p le:
gpc 10
Enabling and Disabling Pixel Coefficients
Pu rp ose:
Enables and d isables FPN and PRN U coefficients.
Syntax:
epc
i i
Syntax Elem ents:
i
FPN coefficients.
0
= FPN coefficients d isabled
1
= FPN coefficients enabled
i
PRN U coefficients.
0
= PRN U coefficients d isabled
1
= PRN U coefficients enabled
Exam p le:
epc 0 1
3.4.3 End-of-line Sequence
Pu rp ose:
Prod u ces an end -of-line sequ ence that p rovid es basic calcu lations
inclu d ing "line cou nter", "line su m ", "p ixels above threshold ",
"p ixels below threshold ", and "d erivative line su m " w ithin the
region of interest. These basic calcu lations are u sed to calibrate
analog offset (
cao
) and calibrate analog gain (
ccg
).
To fu rther aid in d ebu gging and cable/ d ata p ath integrity, the
first three p ixels after Line Valid are "aa", "55", "aa". Refer to the
follow ing table. These statistics refer only to p ixels w ithin the
region of interest.
Syntax:
els
i
Syntax Elem ents:
i
0
Disable end -of-line sequ ence
1
Enable end -of-line sequ ence
N otes:
LVAL is not high d u ring the end -of-line statistics.
Exam p le:
els 1
Table 13: End-of-Line Sequence Description
Location Value
Description
1
A’s
By ensu ring these valu es consistently
toggle betw een "aa" and "55", you can
verify cabling (i.e. no stu ck bits)
2
5’s
All manuals and user guides at all-guides.com