2.2.3 Cam era Link Data Connector for d etails.
Figure 3: Piranha 3 Input and Output Connectors
WARNING: It is extremely important that you apply the appropriate voltages to your camera.
Incorrect voltages will damage the camera. See section 2.4 for more details.
2.2.1 LED Status Indicator
The cam era is equ ip p ed w ith a red / green LED u sed to d isp lay the op eration al statu s of
the cam era. The table below su m m arizes the op erating states of the cam era and the
corresp ond ing LED states.
When m ore than one cond ition is active, the LED ind icates the cond ition w ith the highest
p riority. Error and w arning states are accom p a nied by corresp ond ing m essages fu rther
d escribing the cu rrent cam era statu s.
Table 5: Diagnostic LED
Color of Status LED Meaning
Flashing Green
Cam era initialization or execu ting a long com m and (e.g., flat field
correction com m and s
ccp
or
ccf
)
Solid Green
Cam era is op erational and fu nctioning correctly
Flashing Red
Fatal Error. Cam era tem p eratu re is too high and cam era therm al
shu td ow n has occu rred .
Solid Red
Warning. Loss of fu nctionality (e.g. external SRAM failu re)