background image

 

 

 

 

USERS’ MANUAL 

 

PR

 SYSTEM AND BASE CONSOLE INSTRUCTIONS 

 

Summary of Contents for PROTECTOR+

Page 1: ...USERS MANUAL PROTECTOR SYSTEM AND BASE CONSOLE INSTRUCTIONS ...

Page 2: ...t 4 2 Motion Detector MS18 4 2 1 Mounting the Motion Detector MS18 4 2 2 Using the Motion Detector 4 2 3 Registering a Motion Detector with the Console 4 3 Additional Wireless Sensors optional 4 3 1 Registering an additional Wireless Detector 4 4 Thermostat TS10 optional 4 4 1 Registering a Thermostat with the Console 4 4 2 Using the Thermostats 5 Setting up the Security Base Console SC28 5 1 Sett...

Page 3: ... be used inside and only in dry spaces Do not expose the components to rain or humidity Do not use the product close to a bath swimming pool etc Only connect the adapter to the mains after checking whether the mains voltage is the same as the values on the rating labels Never connect an adapter or power cord when it is damaged In that case contact your supplier Avoid strong mechanical tear and wea...

Page 4: ...r wired sensors zone 31 32 Selectable ALWAYS sensors for emergency purposes 2 Arm Home Modes by pressing ARM HOME once or twice ARM HOME once only D W sensors will be armed Second key press arms also Motion Sensors in zones 1 16 Definable entrance delay on Motion Sensors registered to zones 15 and or 16 Can register a mix of up to 16 wireless remote controls KR18 KR28 SH600 and or emergency sensor...

Page 5: ... not installed 5 Tamper contact 6 AC power supply adapter connections 7 ARM HOME button Alarm function for when you are at home All Door Window Sensors are activated but the Motion Detectors remain unarmed 8 Built in Speaker 9 ARM AWAY button Full alarm All sensors are activated 10 Built in Microphone 11 Wired inputs 12 Telephone connection 13 Emergency battery compartment RECHARGEABLE BATTERIES O...

Page 6: ...needs to be programmed in with the telephone numbers to be able to dial out see 5 2 2 1 2 Connecting the AC adapter Connect the AC adapter to the corresponding connection 6 Plug the flying lead of the adapter into a 230V 50Hz wall socket You can fixate the wire by looping it behind the hooks on the back of the console When connecting the adapter and opening the top compartment of your console you ...

Page 7: ...hoose any of the other available languages as follows To access the menu press the menu UP or menu DOWN button The display now shows ENTER PIN Enter the 4 digit PIN code factory setting 0000 See 8 3 for changing the PIN code The display is cleared and shows a for each number entered When the PIN code has been entered correctly the first menu item will show up on the display Use the menu buttons UP...

Page 8: ...OICE MAIL 11 2 SENSOR MODE Use sensors as emergency sensor See 9 5 SENSOR 27 32 NO ON OFF Used for setting zones 27 to 32 to send Home Automation ON or OFF commands on House Code 1 and Unit Code 7 12 in respond alarm trigger from respective zones 27 32 e g zone 27 is related to UC 7 29 to 9 etc COMFORT To set COMFORT ECONOMY and FROST level temperatures LANGUAGE ENGLISH FRANÇAIS DEUTSCH NEDERLANDS...

Page 9: ...an be registered with your console When pressing the ARM button the LED should flash quickly a few times When the LED lights up and stays lit you need to re initialize the KR18 3 1 2 Registering the Key Chain Remote Control with the Console 1 To access the menu press either the menu UP or DOWN button The display now shows ENTER PIN 2 Enter your 4 digit PIN code factory setting 0000 See 8 3 for cha...

Page 10: ...e plastic cover of the text window you can note which Home Automation Modules can be controlled with each key 7 House Code Switch Used for setting the X10 system Address 3 2 1 Using the Comfort Remote Control IMPORTANT When inserting the batteries the switch should not be in setting 2 1 Install batteries Open the battery compartment on the back of the remote control and place the battery 4x AAA pr...

Page 11: ...me of your door or window Do not close the casing yet 2 Mount the magnet on the moving part of your door of window Make sure that the arrows on the transmitter part see the arrow and the magnet are facing each other when the door or window is closed Keep the distance between the transmitter part and the magnet when door or window is closed as small as possible max 5 mm Door Window Sensors may be h...

Page 12: ...ll read ZONE 1 SET A memory space for a sensor is called a zone If you have more than 1 sensor installed it will show e g ZONE 2 SET ZONE 3 SET ZONE 30 SET You can choose in which zone you want to install the sensor If you want to install the sensor in zone 3 press 3 on the number pad before executing step 5 It s advisable to write down which zone contains which sensor There s space reserved at th...

Page 13: ... any movement during registration Test mode Testing the location of your motion detector 1 Set the switch 5 to 1 2 Press the TEST button 6 until the indicator 1 flashes twice 3 Wait 20 30 seconds 4 Walk in front of the sensor The indicator 1 lets you know when a movement has been detected This allows you to check whether the sensor has been mounted on the right place 5 Press the TEST button again ...

Page 14: ...ectors based on remote panic function or up to 30 sensors in case of wireless alarm sensor function 6 Repeat step 5 for every additional sensor you wish to register 7 Press CLEAR to go back to the first menu item Press CLEAR again to quit the menu If required you can remove Additional Wireless Sensors from the memory This method is described in 8 2 All information on mounting the respective detect...

Page 15: ...d shows a for each number entered 3 When the PIN code has been entered correctly the word INSTALL will displayed 4 Use the menu buttons UP DOWN to go to menu item 3 PHONE NUMS Press OK to select this menu item You can also go to this menu item directly by pressing a 3 on the number pad 5 Use the menu buttons UP DOWN to go to the memory space where you want to enter a telephone number PHONE 1 PHONE...

Page 16: ...8 Door Window Sensors DS18 switch set to MAX when you enter the house This means you have enough time to switch off the system via the console without triggering the alarm The delay times can be changed see 8 1 Also Motion Sensors registered to zone 15 and or 16 will have an entrance delay according the time set This gives the opportunity to have entrances secured via Motion Sensors Besides the Se...

Page 17: ...witch off the system by entering your PIN code on the number pad of the console After entering your PIN code the display will read DISARMED 6 5 Error messages The numbers 1 32 in the display refer to up to 32 zones read sensors These represent up to 30 Door Window Sensors and or Motion Detectors you install plus the 2 hard wired zones The numbers show open zones problem zones and bypassed zones by...

Page 18: ...usehold equipment or TL PL lights into the module Use an AM12 Appliance Switch Module or a LM15 Lamp Module for these types of loads 7 4 Alarm functions of the Lamp Dimmer Modules When Arming the system via the console the lamps on A1 and A2 will be switched on during the Exit Delay As soon as the system is activated the lamp will be switched off When Arming the system via remote control the lamps...

Page 19: ...play will read 1 HOME CNTRL and 2 HEAT COOL select respective timer to set either option 1 for control of lights and appliances or option 2 for timed temperature setbacks Use the menu buttons UP DOWN to check timers you previously set The top menu item is always called NEW TIMER unless all 14 timer points have been set 7 The display will read CHOOSE DAYS Use the number keys to enter the DAYS where...

Page 20: ... 8 on the number pad 5 Select ENTRY DELAY EXIT DELAY ANSWER DELAY or DIAL DELAY and press OK 6 Enter the time required 1 99 seconds Press OK Press CLEAR to delete the values entered 7 Press CLEAR again to quit the menu The entry delay only works for the DS18 Door Window Sensors if set to MAX as well as Motion Sensors registered to zone 15 and or 16 MS18 motion detectors registered to other zones w...

Page 21: ...you go back to the first menu item 9 2 Activating the chime 9 2 1 Built in Chime The console can when in DISARMED mode sound a chime ding dong when a door armed with a Door Window Sensor is opened This ensures that you will always hear if someone is entering your house or small children open a door This function is activated in the factory settings 1 To access the menu press the menu UP or menu DO...

Page 22: ...now reads SET ALWAYS SENSORS You can see on your display top and bottom which zones and sensors have been registered 7 If you want to turn zone 31 into an emergency sensor enter 31 on the number pad and press OK Zone number 31 will start flashing 8 If you also want to turn zone 5 into an emergency sensor enter 5 on the number pad and press OK Zone number 5 will start flashing 9 If you want to turn...

Page 23: ...iren SH10 to address B5 HC 1 UC 5 ATTENTION When using a security system the extra sirens will always work in case of an alarm even when the system is set to silent alarm The Siren SH10 is meant for indoor use and can be plugged into any wall socket 230V 50Hz If Chime is enabled opening a D W sensor gives a pleasant 6 tone message It also gives tones for Exit Delay when Arming one single tone once...

Page 24: ...u press the menu UP or menu DOWN button The display now shows ENTER PIN 2 Enter your 4 digit PIN code factory setting 0000 See 8 3 for changing the PIN code The display is cleared and shows a for each number entered 3 When the PIN code has been entered correctly the word INSTALL will show up on the display 4 Use the menu buttons UP DOWN to go to menu item 7 OPTIONS Press OK to select this menu ite...

Page 25: ...ress set all thermostat levels to Frost level as set to the console 11 Telephone functions 11 1 Calling the security system The SC28 alarm system is equipped with a call in function This means that you can dial in to the console remotely via any telephone or mobile phone You can also control your lights devices and temperature setbacks via your phone The system has a built in speech chip that guid...

Page 26: ...Frost Setting Note The thermostat settings 88 or 88 will only work if the console is Armed Away Otherwise you will get an Error message As soon as you override temperature settings by telephone the only choices are the set point on the thermostat economy or frost The comfort setting of the individual thermostats which is set in the options can only be used by use of a timer event Using the telepho...

Page 27: ...lace the batteries within 30 seconds If the console does not respond to your remote control after replacing the batteries press the PANIC button on your remote control You now need to reregister the remote control using the procedure described in 3 1 2 Door Window Sensor DS18 2x AAA batteries and Motion Detector MS18 2x AA batteries The console checks the battery status of the DS18 sensor If the b...

Page 28: ...vating the zone What to do if you hear a repetitive one tone signal when activating the alarm This is normal When activating the alarm there is an exit delay of one minute to leave your house You can alter this delay see 8 1 After one minute the tone will stop and the system will be switched on What if you cannot switch the light on or off using the Lights ON or Lights OFF button on the remote con...

Reviews: