Page
41
of
73
SK2015
FSTDC
‐
V/P
‐
ECM
‐
001
C.7.
Auto
Fan
Speed
COOL
MODE
HEAT
MODE
Fan
speed
cannot
change
until
it
has
run
for
more
than
30
seconds.
Fan
speed
is
regulated
according
to
the
profile
below.
Fan
speed
cannot
change
until
it
has
run
for
more
than
30
seconds.
Fan
speed
is
regulated
according
to
the
profile
below.
After
30
seconds
the
fan
speed
is
modulated
according
to
the
difference
between
the
room
temperature
and
the
set
temperature.
The
controller
adjusts
the
motor
signal
input
from
0
to
5VDC
by
PID
calculation
every
10
seconds.
The
air
flow
is
adjusted
from
15%
to100%.
C.8.
Modulating
Valve
Control
Under
Energy
Saving
Mode
If
the
modulating
valve
is
used,
the
water
flow
is
adjusted
from
0
to
100%
according
to
the
room
temperature
and
set
temperature.
The
controller
adjusts
the
modulating
valve
signal
input
from
0
to
10VDC
by
PID
calculation
every
10
seconds.
C.9.
Swing
/
Louver
For
remote
handset
with
Control
Box
–
I
(Integrated
Full
Control
Version)
Whenever
the
indoor
fan
is
running,
the
louver
can
swing
or
stop
at
the
desired
position.
Louver
angle:
0~100
º,
opens
clockwise
with
widest
angle
at
100
º.
Swing
angle:
35~100
º,
opens
clockwise
to
68º.
Below
are
the
4
fixed
positions
which
can
be
set
from
wireless
LCD
handset.
Position
Angle
against
vertical
1
35
º
2
57
º
3
83
º
4
100
º
For
wired
wall
pad
with
Control
Box
–
I
(Integrated
Full
Control
Version)
Louver
angle:
0~100
º,
opens
clockwise,
with
widest
angle
at
100
º.
Swing
angle:
35~100
º,
opens
clockwise
to
68º.
User
may
stop
louver
at
any
desired
position
between
35~100
º.
C.10.
Buzzer
If
a
command
is
received
by
the
air
conditioner,
the
master
unit
will
respond
with
2
beeps
for
each
setting,
while
the
slave
unit
will
respond
with
1
beep.
High
Tr
Medium
Low
Low
Ts+3C
Ts+2C
Ts+1C
Ts
High
Medium
Low
High
Tr
Low
Low
Medium
Ts
Ts
‐
1C
Ts
‐
2C
Ts
‐
3C
Low
Medium
High
Summary of Contents for FDLA-09
Page 1: ...SK2018 GLOBAL FDLA V P AC 001 FDLA V P AC MOTOR...
Page 27: ...Page 26 of 51 SK2018 GLOBAL FDLA V P AC 001 Configuration Settings...
Page 53: ...FDHD V P AC MOTOR...
Page 69: ...B 1 4 4 Electrical connections T Configuration standard version...
Page 74: ...Wiring Diagram D 2 SK NCPDWH 001b S Configuration Full Control PCB...
Page 76: ...Configuration Settings D 3...
Page 111: ......
Page 112: ...SK2019 FCSD H V P ECM 001 FCSD H V P ECM MOTOR...
Page 190: ...SK2019 FCSD H V P ECM 001...
Page 191: ...Page 1 of 59 SK2015 FMCD V EC 001 FMCD ECM MOTOR...
Page 210: ...Page 20 of 59 SK2015 SWC V EC 001 D 1 3 Wiring Diagram SK NCSWC 001...
Page 233: ...Page 43 of 59 SK2015 SWC V EC 001 D 4 2 Wiring diagram SK NCSWC 002...
Page 248: ...Page 58 of 59 SK2015 SWC V EC 001 Troubleshooting Guide E 4...
Page 249: ...Page 59 of 59 SK2015 SWC V EC 001...
Page 250: ...FSTD C V P ECM MOTOR...
Page 256: ...Page 7 of 73 SK2015 FSTDC V P ECM 001 A 2 Unit Appearance FSTDC VAR FSTDC HAR FSTD...