D.1.8.
Louver
For
remote
handset
Whenever
the
indoor
fan
is
running,
the
louver
can
swing
or
stop
at
the
desired
position.
Louver
angle:
0~100º,
opens
clockwise
with
widest
angle
at
100º.
Swing
angle:
35~100º,
opens
clockwise
to
68º.
Below
are
the
4
fixed
positions
which
can
be
set
from
wireless
LCD
handset.
Position
Angle
1
35º
2
57º
3
83º
4
100º
For
wired
wall
pad
Louver
angle:
0~100º,
opens
clockwise,
with
widest
angle
at
100º.
Swing
angle:
35~100º,
opens
clockwise
to
68º.
User
may
stop
louver
at
any
desired
position
between
35~100º.
D.1.9.
Buzzer
If
a
command
is
received
by
the
air
conditioner,
the
master
unit
will
respond
with
2
beeps
for
each
setting,
while
the
slave
unit
will
respond
with
1
beep.
D.1.10.
Auto
Restart
The
system
uses
non
‐
volatile
memory
to
save
the
present
operation
parameters
when
system
is
turned
off
or
in
case
of
system
failure
or
cessation
of
power
supply.
When
power
supply
resumes
or
the
system
is
switched
on
again,
the
same
operations
as
previously
set
will
function.
Operation
parameters
when
using
a
handset
are
Mode,
Set
Temperature,
Swing,
and
Fan
Speed
when
using
a
wall
pad
parameters
are
Mode,
Set
Temperature,
Swing,
and
Fan
Speed,
as
well
as
the
7
‐
day
ON/OFF
Timer
program.
D.1.11.
Operation
Of
Control
Panel
On
High
‐
Wall
Unit
D.1.11.1.
On/Off
Switch
This
is
a
tact
switch
to
select
COOL
→
HEAT
→
OFF
opera on
mode.
In
COOL
mode,
the
set
temperature
of
the
system
is
24ºC
with
auto
fan
speed
and
swing.
There
are
no
timer
and
SLEEP
modes.
In
HEAT
mode,
the
set
temperature
of
the
system
is
24ºC
with
auto
fan
speed
and
swing.
There
are
no
timer
and
SLEEP
modes.
Master
unit
that
does
not
use
a
LCD
wall
pad
will
globally
broadcast.
Note:
When
button
pressing
is
effective,
the
master
unit
buzzer
will
beep
twice
and
the
slave
unit
will
beep
once.
D.1.11.2.
Electric
Heater
Safety
Switch
(on
control
PCB)
Before
the
electrical
heater
is
turned
on,
the
EH
safety
switch
must
be
closed.
If
this
contact
is
opened
continuously
≥
1
second,
the
heater
will
be
turned
off
immediately
and
report
an
error.
Once
the
contact
is
returned
to
the
closed
position
≥
60
seconds,
reset
the
error
and
the
heater
will
start
again.
Should
the
EH
safety
switch
be
opened
≥
3
times
within
60
minutes,
the
heater
is
not
allowed
to
start
anymore.
Turn
off
the
unit
to
reset
the
fault,
provided
that
the
switch
has
returned
to
the
closed
position.
Summary of Contents for FDLA-09
Page 1: ...SK2018 GLOBAL FDLA V P AC 001 FDLA V P AC MOTOR...
Page 27: ...Page 26 of 51 SK2018 GLOBAL FDLA V P AC 001 Configuration Settings...
Page 53: ...FDHD V P AC MOTOR...
Page 69: ...B 1 4 4 Electrical connections T Configuration standard version...
Page 74: ...Wiring Diagram D 2 SK NCPDWH 001b S Configuration Full Control PCB...
Page 76: ...Configuration Settings D 3...
Page 111: ......
Page 112: ...SK2019 FCSD H V P ECM 001 FCSD H V P ECM MOTOR...
Page 190: ...SK2019 FCSD H V P ECM 001...
Page 191: ...Page 1 of 59 SK2015 FMCD V EC 001 FMCD ECM MOTOR...
Page 210: ...Page 20 of 59 SK2015 SWC V EC 001 D 1 3 Wiring Diagram SK NCSWC 001...
Page 233: ...Page 43 of 59 SK2015 SWC V EC 001 D 4 2 Wiring diagram SK NCSWC 002...
Page 248: ...Page 58 of 59 SK2015 SWC V EC 001 Troubleshooting Guide E 4...
Page 249: ...Page 59 of 59 SK2015 SWC V EC 001...
Page 250: ...FSTD C V P ECM MOTOR...
Page 256: ...Page 7 of 73 SK2015 FSTDC V P ECM 001 A 2 Unit Appearance FSTDC VAR FSTDC HAR FSTD...