Page 1: ...R 9916 Health Clean DEHUMIDIFIER AIR PURIFIER Thank you for choosing our product For proper operation please read and keep this manual carefully Instruction Manual ...

Page 2: ...fore Operation 4 Operation Instructions Operation Method 5 Drainage Option 8 Maintenance Clean and Maintenance 10 Malfunction Troubleshooting 12 Defrost Procedure 14 Note Graphics in this manual are only for reference Please refer to actual products for specific details Content ...

Page 3: ... C or above 32 C Allow at least 20 30 cm of air space on all sides of the unit Close all doors windows and other outside openings of the room to improve the working effect Please keep the air inlet outlet clean and not blocked Avoid direct sunlight from the bucket or 1 NNotes Left 20cm or more Right 20cm or more UP 30 cm or more ...

Page 4: ...ier When nobody is taking care of the unit please turn it off and remove the power plug or disconnect power Do not repair or disassemble the unit by yourself If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Cleaning and user maintenance shall not be made by children without supervision If abnormal cond...

Page 5: ...Parts Name Front Side Back Side 3 CONTROL PANEL ROLLERS WATER BUCKET Air Outlet AIR FILTER HANDLE ...

Page 6: ...the room temperature less than 18 C The defrosting processmay start up and operatefor some time about 5 minutes automatically every 25 minutes or even longer During the defrosting operation the dehumidification function and air purification function may intermit Please don t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation This dehumidifier can t b...

Page 7: ...nage method Each time pressing the effective button on the control panel will give out a beep sound Notes 1 Stant By Button Set humidity set the range of 30 80 If you press this button for 5 sec you will see the actual level of temperature in the room Sleep Mode After entering sleep mode the light in the control panel close Air Cleaner If you choose the compressor stop to work and the unit work as...

Page 8: ...l Timer Off Under the condition that this function is turned on press the button TIMER until the timer screen 00 h Set Timer On When unit is off press this button and the Timer Indicator will be blink Press this button to set Timer On or Timer Off Timing range 01 24h Set Timer Off When unit is on press this button and the Timer Indicator will be blink Timer will increase each time you press the bu...

Page 9: ...k into the correct place 2 Auto Stop When bucket is full removed or not placed correctly or the humidity is 5 lower than the set humidity unit will automatically stop 3 Memory Function If power is lost all of the control settings are remembered So when power is restored the unit will start back up in the settings it was in when power was lost 1 Alarm Warning Other Instructions Dry Cloths In this o...

Page 10: ...hose is connected water will be drained out through it instead of into the bucket 1 Hold the handles on both sides of the water bucket and pull it out following the arrow direction Attention Pull out the bucket carefully in case the water may 2 Empty the bucket by grasping the handle on the top of bucket with one hand and grasping the bottom of bucket with the other hand 8 Handle Bucket ...

Page 11: ...id Note that drain hose should not be pressed otherwise water can not be drained out 4 Replace the bucket Make sure the drain hose goes through the bucket s drain Note When you want to take off the drain hose prepare a receptacle to collect water from the nozzle Set an air clean filter to a dehumidifier Notes The time life of the ionic and carbon filter is based on the environmental air normally i...

Page 12: ...Warning Otherwise the evaporator will catch dust and affect unit s performance Do not dry the air filter with fire or electric hair dryer Otherwise the air filter may be unshaped or caught on fire Don t use dust catcher or brush to clean the air filter Otherwise the air filter may be destroyed Check Before Use season Check whether air outlet is blocked Check whether power plug and power socket are...

Page 13: ...will start to defrost automati cally Compressor will stop for a brief period of time fan will operate in high fan speed Little or no effect in dehumidifyng normal operation Due to temperature rising of heat exchanger the air may have some strange smell at the beginning emitted has musty odor Unit has noises There might be some noise if unit is operating on Swooshing sound is heard Problem of Water...

Page 14: ...ter is full in the bucket Bucket has been removed Empty the bucket and replace it If you want the air drier press button to lower the for unit to dehumidify continuously normally but it can Humidity is set too high not start up Unit s Malfunction Codes Units Condition Dispay Code E1 Humidity Sensor is damaged Display Code E2 Temperature Sensor is damaged Defrost procedure Please note if the ROOM t...

Page 15: ...ste collection centre or to a dealer providing this service Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving form inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the prod...