42
Command button
* 58 * T * C * AT **
configuration 1 T: button to be personalised
23
personalisation C: command n° (see table of personalised
commands)
acces AT: access type
to commands
0: direct access
via code
1: access via code
Allocation of a
* 60 * D * G * T **
group 1 D: detector n°
24
programmed detector G: group n° from 1 to 8
T: time delay = 0: immediate
1: time-delayed
2: combined
Uninhibitable detector
* 61 * detector n° * ? **
inhibitable 0: inhibitable
26
1: uninhibitable
Chime
* 62 * detector n° * ? **
disabled 0: disabled
28
1: enabled
Vocal personalisation
* 66 * T * P # “message” #
no pre-recorded T: product type
21
of products
“message repeated” *
message 0: hardwired input
2: detector
3: command
4: siren
5: dialler**
7: radio repeater relay or receiver
P: product n° from 0 to 80
Date
* 70 * DD * MM * YY **
DD: 01 from 01 to 31
18
MM: 01 from 01 to 12
YY: 12 from 00 to 99
Time
* 71 * HH * MM **
HH: 00 from 00 to 24
18
MM: 00 from 00 to 59
Type of warning
* 72 * ? **
audible 0: disabled
25
indication 1: audible
Type of deterrence
* 73 * ? **
audible 0: disabled
25
indication 1: audible
Type of prealarm
* 74 * ? **
audible 0: disabled
25
indication 1: audible
Vocal personalisation
* 131 * G # “message” #
no pre-recorded G: group n° from 1 to 8*
21
of groups
“message repeated” *
message max duration 3 s
Product inhibition
* 190 * T * product n° **
- T: product type:
29
Product reactivation
* 191 * T * product n° **
-
2: detector
29
Deletion of a
* 194 * T * product n° **
-
3: remote control unit
15
programmed product
4: siren
5: dialler **
7: radio repeater relay or receiver
n°: product n°
Overall deletion
* 195 ***
- -
15
of programming
Deletion of access
* 196 ***
- installer code: 1111
15
codes master code: 0000
remote monitoring code: 2222
Deletion of parameters
* 197 ***
- return to factory parameters
29
Overall deletion
* 198 ***
- overall deletion of recognition programming
29
and return to factory parameters
Automatic Arm/Disarm
* 511 * ? **
disabled 0: disabled
28
function 1: enabled
Parameter Parameter-setting Factory Possible values Page
description sequence parameters
Control panel parameters (cont.)
* Depending on type of control panel ** If transmission module installed