33
9. Performing a real test
1.
Close the exits and leave the protected areas
for a period of 90 s.
2.
Arm the system
ƒ
• on receipt of the command, the control panel
responds:
“bip, Armed”
3.
Wait until the end of the exit time delay
ƒ
• the control panel issues the voice message:
“Armed”
4.
Enter a protected room
ƒ
• the control panel and siren are triggered,
• the telephone dialler calls the programmed
correspondents according to the type
of event transmitted (1)
5.
Let the sirens sound for 30 s then stop
the system
ƒ
• on receipt of the
“Off”
command, the sirens stop
and the control panel issues the following type
of voice message:
6.
Check the alarm has been transmitted by telephone
to the programmed correspondents (1) (2).
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
(
“bip, Off, on 21/04/2012 at 7:30 PM,
intrusion, detector 3, group 1”
“bip, Armed”
“Armed”
First put the system in user mode.
USER MODE
IMPORTANT
• The sounding level of the siren can cause hearing disorders and the necessary precautions must therefore be taken when
testing triggering.
• Let correspondents know beforehand.
(1) If transmission module installed.
(2) Disarming the system stops transmission of the call to correspondents (for calls to individuals only).