19
If a fault occurs, system arming can be blocked.
The control panel can be programmed for 5 types of response.
To activate blocked system arming, enter:
Factory: 4 (blocked if supervision command not received (20 min) and exits checked at the end of the exit time delay)
from 0 to 4
Response Value
arming blocked disabled 0
arming blocked if at least one of the following faults occurs: 1
• power fault
• tamper fault
• radio link fault
• exits open
It is possible to override blocked arming: 4 commands in less than 10 s.
arming blocked if at least one of the following faults occurs: 2
• tamper fault,
• exit(s) open
It is impossible to override blocked arming.
blocked if supervision command not received within 20 min: 3
• tamper fault
• exit(s) open upon arming
It is impossible to override blocked arming.
blocked if supervision command not received within 20 min and exits checked 4
upon arming and at the end of the exit time delay:
• tamper fault
• exit(s) open
• management of open exits upon arming and during exit time delay.
It is impossible to override blocked arming.
IMPORTANT: the control panel issues 3 short beeps to indicate errors.
5.6 Blocking system arming
5.7.1 Exit time delay
• To modify the exit time delay on all groups, enter:
Factory: 90 s.
• To modify the exit time delay on one of the groups, enter:
Factory: 90 s.
from 0 to 90 s
from 0 to 90 s
group n°
from 1 to 8
NOTE: when arming several Groups with
time delays, the longest time delay will be
effective.
“bip + value entered”
“bip + value entered”
• To modify the exit time delay on several groups, enter:
Factory: 90 s.
Example: for an exit time delay of 40 s for groups 1, 4 and 6, enter:
...
from 0 to 90 s
group n°
from 1 to 8
“bip + value entered”
“bip, 1, 4, 6, 40”
5.7 Setting the time delay parameters