12
Different types of triggering possible: • immediate,
• time-delayed,
• combined.
Immediate triggering
In the event of intrusion, the alerts and deterrents are
immediately triggered.
3.2 Programming an intrusion detector to be recognised by the control panel
Door/window detector 1
GR1 immediate
Motion detector 2
GR1 immediate
keypad
door
window
Time-delayed triggering
In the event of intrusion, the alerts and deterrents are
triggered at the end of the entrance time delay.
Door/window detector 1
GR1 time-delayed
Motion detector 2
GR1 time-delayed
keypad
Example:
• The user enters his/her home:
Door/window detector 1 is activated
and
motion
detector 2
becomes
time-delayed
hence allowing the
user to reach the keypad to disarm the system.
Combined triggering
A combined detector is immediately triggered if it is activated first. Its triggering is time-delayed if another time-delayed
detector is activated first.
• In the event of intrusion via the window:
Door/window detector 1 is not activated, motion
detector 2 triggering becomes immediate
and the
alerts and deterrents are immediately triggered.
Door/window detector 1
GR 1 time-delayed
Motion detector 2
GR1 combined
keypad
Door/window detector 1
GR 1 time-delayed
Motion detector 2
GR1 combined
keypad
door
window
door
window
door
window