17
Number of access code digits
Before modifying access codes, the
number of access
code digits
must first be determined.
This modification must be done using the factory code.
Extending the number of digits applies to:
• the master code,
• the installer code,
• the remote monitoring centre code.
To modify the number of digits, enter:
Example:
To extend access codes to 6 digits, enter:
“bip, 6”
number of digits (from 4 to 6)
The master code is designed for the main user and allows the following:
• complete use of the system (all commands),
• access to TEST mode and USER mode,
• remote operation of the system over the phone,
• control (authorisation or inhibition) of User codes,
• control of access to remote management and remote configuration.
To ensure system confidentiality, access codes must be modified.
To do this, enter:
Factory: 0000
Example:
To replace the factory master code “0000” with the new code “1234”, enter:
old
master code
new
master code
new
master code
“beeep”
Before modifying the installer code, check that the control panel is in installation mode.
To do this, proceed as follows:
then
IN
ST
AL
LA
TI
ON
M
OD
E
master code
installer code
The installer code is for use by the installer.
It allows access to system installation, programming and maintenance operations:
• INSTALLATION MODE access,
• remote configuration.
To ensure system confidentiality, the installer code must be modified.
To do this, proceed as follows:
Factory: 1111
old installer
code
new code
installateur
new code
installateur
5.2 Modifying the master code
5.3 Modifying the installer code
Number
of digits
Factory code
installer
master
remote
monitoring
centre
4 (factory)
1111
0000
2222
5
11111
00000
22222
6
111111
000000
222222