10
2.6.3 When using with the mains power module and Li-ion rechargeable battery (not supplied)
5.
Position the mains power module on the guide rails.
6.
Slide the module upwards until it locks into position.
Locking key
3.
Loosen the internal mains power
module locking screw.
4.
• Connect the mains power cable type H05VVF 2 x 0.75 mm
2
,
twin with diameter between 5 mm and 7.5 mm to the terminal block.
• Install a cable clamp.
• Put the cover back and tighten the closing screw.
Cover
Locking screw
230 V
mains cable
clamp (not
supplied)
Electrical
shock hazard
1.
Connect the rechargeable back-up battery
to the 2-point connector.
2.
Clip the back-up battery into its compartment.
Battery
2-point
connector
IMPORTANT: only use 4.5 V DC
power module
RXU01X internal mains power module:
200-240 VAC
50-60 Hz / 4.5 VDC 2.2 A
double insulation symbol,
220 V power supply
without earth connection)
Connect to terminal “N”
of the terminal block
(blue cable)
Connect to terminal “L”
of the terminal block
7 mm +/-1
28 mm +/-2
Strip 28 mm of the outer cover, and 7 mm of insulation
from the inner cores
Terminal L
Terminal N