16
5. Main parameter-setting operations
5.1 Modifying access codes
If the system has a command keypad, any modifications to the control panel must be repeated on the command keypad.
To ensure system confidentiality, access codes must be modified:
• the master code for use by the user,
• the installer code.
The master code can be modified in the 3 operating modes:
IN
ST
AL
LA
TI
ON
M
OD
E
TE
ST
M
OD
E
US
ER
M
OD
E
or
or
IMPORTANT: all parameter-setting must be performed using TwinLoad
®
software available in the Installers section at
www.daitem.co.uk.
4. Changing operating modes
The control panel keypad or command keypad can be used to check the mode.
Operating mode
Keypad sequence Message
system status, installation mode and any faults
e.g.
“bip, system status,
installation mode
”
system status, test mode and any faults
e.g.
“bip, system status,
test mode
”
system status (disarming and any faults)
e.g.
“bip, system status,
off
”
INSTALLATION
MODE
TEST MODE
USER MODE
master code
The operating mode is changed using the factory master code “0000” then the factory installer code “1111” as shown
below:
IMPORTANT: for security reasons, the control panel automatically switches back to user mode after 4 hours without a
command being issued.
INSTALLATION
MODE
TEST MODE
USER MODE
installer code
m
as
ter
co
de
m
as
ter
co
de
ins
talle
r c
od
e
ins
talle
r c
od
e
1 flash every 5 s
2 flashes
every 10 s