27
Radio fault indications
To modify the control panel indication level in the event of faults, enter:
Factory: indication and telephone transmission (1)
“bip, n° ?”
0: indication disabled
1: indication and telephone transmission (1)
2: local indication
Radio tamper
The control panel monitors the availability of radio links. If the radio links are tampered with, the control panel can trigger an
alarm (loud sounding for 90 s).
To modify radio tamper alarm triggering, enter:
Factory: enabled 24/24 (transmission (1) + indi events log alarm memorisation)
0: disabled
1: enabled 24/24 (transmission (1) + indi events log alarm memori alarm triggering)
2: enabled 24/24 (transmission (1) + indi events log alarm memorisation)
Example 1:
Parameter 26 on the control panel is set at 0. Whatever the configuration of the other devices and the duration of the media
cut, the event will only be memorised in the events log and indicated vocally.
Exemple 2:
Parameter 26 is set at 2 on the control panel, at 1 on the dialler and at 1 on the internal and external sirens.
• If the system is totally armed and the PSTN media cut (or GSM interference) lasts longer than 1 minute:
- the control panel will memorise the event in the events log, provide vocal indication of the event, transmit the fault
message if back-up media is available and trigger the siren,
- the stand-alone dialler will use the back-up media to transmit the media loss followed by the media restoral (when it
becomes available again),
- the sirens will trigger loudly.
• If the system is disarmed or one or several groups are disarmed:
- the control panel will memorise the event in the events log, provide vocal indication of the event and transmit the fault
message if back-up media is available,
- the stand-alone dialler will transmit the media loss followed by the media restoral (when it becomes available again),
- the siren will not respond.
Management of tamper alarms in installation mode
If one of the system products triggers a tamper alarm, the control panel can activate:
• a telephone transmission (1),
• the relay outputs (if programmed for “all alarms” (2)),
• memorisation in the events log.
To modify this configuration, enter:
Factory: enabled
0: disabled, no triggering
1: enabled, triggering of tamper alarm
(1) If transmission module installed.
(2) If input/output card connected.
Programming connected inputs and outputs (if input/output card connected)
A. Programming hardwired inputs
The hardwired input can be programmed according to the control panel response required.
To set this parameter, use the control panel keypad and proceed as follows:
Factory: 2 (intrusion)
Type of input
• 0: disabled
• 1: exit
• 2: intrusion
• 3: deterrence
• 4: prealarm
• 5: fire
• 6: technical
• 7: emergency call
• 8: alert
• 9: silent alarm
• 10: chime
“bip + selected option”