Names and Functions
SiUS371901EB
109
Part 3 Remote Controller
About icons on the information screen
The items displayed vary depending on the indoor unit you are using.
Icon
Name
Description
Information
Indicates an information screen.
MAIN/SUB remote
controller
Displayed when used as the MAIN/SUB remote controller.
1=main, 2=sub
Bluetooth*
Indicates that the controller is communicating with a
mobile device, for use with the app.
Clock not set
Indicates that the clock needs to be set again.
Setback
Indicates that the indoor unit is operating under setback
conditions.
Under centralized
control
Indicates that the system is controlled by central control
equipment (optional accessory) and that control of the
system by the controller is limited.
Changeover
controlled by the
master indoor unit
Displayed:
The remote controller does not have master control.
Unable to select heating/cooling operation.
Blinking:
None of the remote controllers in the system have master control.
Can be set as the master controller during this time.
Not Displayed:
The remote controller has master control.
Able to select heating/cooling operation.
Backup
Indicates that backup operation is being carried out.
Energy savings
Indicates that the system’s energy consumption is being
limited, and that it is running with restricted capacity.
Individual airflow
direction
Indicates that the individual airflow direction setting is
enabled.
Test operation
Indicates that Test Operation mode is active.
Stand by for Defrost/
Hot start
Indicates that the defrost/hot start mode is active.
Self-cleaning filter
operation
Indicates that selfcleaning filter operation is active.
Inspection
Indicates that the indoor or outdoor unit is being
inspected.
Periodic inspection
Indicates that the indoor or outdoor unit is being
inspected.
Ventilating operation
Indicates that ventilating operation is being carried out.
Warning
Indicates that an error occurred, or that an indoor unit
component needs to be maintained.
* The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc.
and use of such marks by Daikin industries, LTD. is under license. Other trademarks and trade
names are those of their respective owners.
Summary of Contents for REYQ72-432XAYCU
Page 455: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 448 REYQ144 168XATJU REYQ144 168XATJA 2D119206B ...
Page 457: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 450 REYQ144 168XAYDU REYQ144 168XAYDA 2D119208C ...
Page 461: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 454 FXZQ05 07 09 12 15 18TAVJU 3D110443A ...
Page 463: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 456 FXEQ07 09 12 15 18 24PVJU 3D098557A ...
Page 464: ...Wiring Diagrams SiUS371901EB 457 Part 7 Appendix FXDQ07 09 12 18 24MVJU C 3D050501C ...
Page 468: ...Wiring Diagrams SiUS371901EB 461 Part 7 Appendix FXHQ12 24 36MVJU 3D048116C ...
Page 469: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 462 FXAQ07 09 12 18 24PVJU 3D075354F ...
Page 475: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 468 VAM1200GVJU 3D073270D ...
Page 478: ...Wiring Diagrams SiUS371901EB 471 Part 7 Appendix BS6 8Q54TVJ 2D089122B ...
Page 479: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 472 BS10 12Q54TVJ 2D089121B ...
Page 481: ...SiUS371901EB Wiring Diagrams Part 7 Appendix 474 BSF6 8Q54TVJ 2D123905A ...