Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
d
c
a
a
b
a
Screw (swing raster motor assembly)
b
Swing raster motor assembly
c
Fan guard
d
Swing raster motor rod
8
Connect the swing raster motor rod to the swing raster shaft using soft tools.
9
Tighten the 2 screws to properly fix the swing raster motor assembly.
10
Install the fan guard.
11
Connect the drain hose to the indoor unit.
a
b
a
Screw (drain hose)
b
Drain hose
12
Install the drain hose fixation bracket. Install and tighten the screw.
13
Install the switch box, see
Is the problem solved?