2
Install the main PCB in the correct location in the switch box.
j
j
k
f
g
a
b
d
c
e
h
h
i
j
j
j
j
j
a
Power supply wires from X1M
b
Ferrite core (power supply wires)
c
Tie strap (power supply wires)
d
Screw (ground wiring)
e
Ferrite core (ground wiring)
f
Connector X12A
g
Compressor connector
h
Tie strap (compressor harness)
i
Ferrite core (compressor harness)
j
Screw
k
Main PCB
3
Install and tighten the screws.
4
Fix the ferrite core (for compressor harness) to the switch box (fixation plug).
5
Install new tie straps to fix the compressor harness to the switch box.
6
Install the ground wiring on the switch box and fix using the screw.
7
If applicable: Connect the connector X12A.
8
Fix the ferrite core (for power supply wiring) to the switch box (fixation plug).
9
Connect the power supply wiring to the main power supply terminal X1M.
10
Fix the power supply wiring to the switch box using a new tie strap.
11
Connect all other connectors to the main PCB.
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
226].
Is the problem solved?
Action
Yes
No further actions required.
No
continue with the next procedure.