![background image](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072086.webp)
4
|
Components
Service manual
86
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
a
b
A
A
Class 42~71 unit
a
Expansion valve coil
b
Expansion valve coil harness
3
Cut all tie straps that fix the expansion valve coil harness.
4
Disconnect the expansion valve coil connector S20 from the main PCB.
5
Remove the expansion valve coil (and harness) from the unit.
6
To install the expansion valve coil, see
85].
To remove the expansion valve body
Prerequisite:
Recuperate the refrigerant from the refrigerant circuit, see
212].
Prerequisite:
If needed, remove any parts or insulation to create more space for
the removal.
1
Remove the expansion valve coil, see
85].
2
Remove the putty. Keep for re-use.
a
b
c
A
a
a
a
A
Class 20~35 unit
a
Putty
b
Expansion valve pipe
c
Expansion valve body