![Daikin Perfera RXM20R Service Manual Download Page 176](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072176.webp)
4
|
Components
Service manual
176
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
b
a
c
d
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
5
Remove the swing flap motor from the coupling piece.
6
To install the swing flap motor, see
To install the swing flap motor
1
Install the coupling piece on the swing flap motor.
2
Install the swing flap motor in the correct location on the indoor unit.
b
a
c
d
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
3
Install and tighten the screw to fix the swing flap motor.
4
Install the swing flap.
5
Install the swing raster motor, see
185].
6
153].
Is the problem solved?
Action
Yes
No further actions required.