![Daikin Perfera RXM20R Service Manual Download Page 104](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072104.webp)
4
|
Components
Service manual
104
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
a
c
d
b
c
d
d
e
f
a
Ferrite core
b
DC fan motor wiring harness
c
Hook
d
Screw (fan motor cover)
e
Fan motor cover
f
Wiring harness retainer
4
Route the DC fan motor wiring harness through the hooks and install the
harness retainer. Make sure the wiring harness is also routed through the
hooks located behind the harness retainer.
5
Lock the ferrite core on the DC fan motor wiring harness.
6
Install a new tie strap to fix the ferrite core to the indoor unit.
7
Install the turbo fan assembly, see
100].
To install the turbo fan assembly
1
Install the turbo fan assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged turbo fan assembly.
2
Install and tighten the nut to fix the turbo fan assembly.
a
a
a
b
c
a
d
a
Screw (bellmouth)
b
Bellmouth
c
Nut (turbo fan assy)
d
Turbo fan assy