![Daikin Perfera RXM20R Service Manual Download Page 103](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072103.webp)
4
|
Components
Service manual
103
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
17
To install the turbo fan assembly, see
To remove the DC fan motor assembly
1
Remove the turbo fan assembly from the DC fan motor assembly, see
100].
2
Cut the tie strap and unlock the ferrite core.
a
c
d
b
c
d
d
e
f
a
Ferrite core
b
DC fan motor wiring harness
c
Hook
d
Screw (fan motor cover)
e
Fan motor cover
f
Wiring harness retainer
3
Route the DC fan motor wiring harness out of the hooks.
4
Remove the 3 screws and remove the fan motor cover.
5
Unfasten the hooks and remove the wiring harness retainer.
6
Route the DC fan motor wiring harness out of the hooks (behind the harness
retainer).
7
Remove the DC fan motor assembly from the indoor unit.
8
To install the DC fan motor assembly, see
To install the DC fan motor assembly
1
Install the DC fan motor assembly on the fan motor cover.
2
Install the fan motor cover with DC fan motor assembly on the correct
location.
3
Install and tighten the 3 screws to fix the fan motor cover.