![Daikin Perfera RXM20R Service Manual Download Page 223](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072223.webp)
6
|
Maintenance
Service manual
223
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
6.7 To clean the titanium apatite deodorising filter and the silver
particle filter (Ag-ion filter)
INFORMATION
Clean the filter with water every 6 months.
1
Remove:
▪
for class 15~42:
silver allergen removal air purifying filter from the tabs
▪
for class 50~71:
titanium apatite deodorising filter and the silver allergen
removal air purifying filter from all 4 claws.
a
Claw
2
Remove the dust from the filter with a vacuum cleaner.
3
Soak the filter for 10 to 15 minutes in warm water.
Note:
(class 50~71)
Do NOT remove the filter from the frame.
Class 15~42
Class 50~71
4
After washing, shake off remaining water and dry the filter in the shade. Do
NOT wring out the filter when removing water.
6.8 To replace the titanium apatite deodorising filter and the silver
particle filter (Ag-ion filter)
INFORMATION
Replace the filter every 3 years.