![background image](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072162.webp)
4
|
Components
Service manual
162
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
1
2
Floor standing units
1
2
Remove the 4 screws, remove the grille from 4 tabs on the top and remove
the front grille while pulling it toward you.
4×
b
a
a
Front grille
b
Tabs
To remove the electrical wiring box cover
ATXM-R and FTXM-R units
TO OPEN THE SERVICE COVER
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
a
b
a
Service cover screw
b
Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
TO REMOVE THE ELECTRICAL WIRING BOX COVER
Prerequisite:
Remove the front grille.
1
Remove 1 screw from the electrical wiring box.