![Daikin Perfera RXM20R Service Manual Download Page 178](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072178.webp)
4
|
Components
Service manual
178
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
Pins
Measured resistance (Ω)
2-3
706.8~813.2
2-4
2-5
3-4
3-5
4-5
Swing flap motor resistance
measurements are correct?
Action
Yes
Replace the swing flap motor wiring
harness, see
No
Replace the swing flap motor, see
178].
Repair procedures
To remove the swing flap motor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
153].
1
Remove the switch box, see
2
Remove the main swing flap from the indoor unit (by clicking it out).
3
Remove the secondary swing flap from the indoor unit (by clicking it out).
4
Remove the screw from the swing flap motor.
b
a
c
d
a
Main swing flap
b
Secondary swing flap
c
Screw (swing flap motor fixation)
d
Swing flap motor
5
Remove (pull back) the swing flap motor from the indoor unit.
6
Disconnect the wiring harness from the swing flap motor.
7