![Daikin Perfera RXM20R Service Manual Download Page 67](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072067.webp)
4
|
Components
Service manual
67
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
a
a
A
A
Class 42~71 unit
a
Compressor pipe
8
Stop the nitrogen supply when the piping has cooled down.
INFORMATION
It is ALSO possible to cut the component pipe(s) using a pipe cutter. Make sure to
remove the remaining component pipe end(s) from the refrigerant pipes by heating
the brazing point(s) of the component pipe(s) using an oxygen acetylene torch.
9
Remove the nuts and bolts and remove the compressor from the unit.
b
c
a
c
A
A
Class 20~35 unit
a
Nut
b
Compressor
c
Damper