3
|
Components
Service manual
183
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a
Screw (drain hose)
b
Drain hose
4
Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
d
c
a
a
b
a
Screw (swing raster motor assembly)
b
Swing raster motor assembly
c
Fan guard
d
Swing raster motor rod
5
Remove the fan guard.
6
Disconnect the swing raster motor rod from the swing raster shaft.
7
Remove the swing raster motor assembly from the indoor unit.
8
Disconnect the rod and link from the swing raster motor. Keep the rod and
link for reuse.
b
a
c
d
c
a
Rod
b
Link
c
Screw (swing raster motor fixation)
d
Swing raster motor
9
Remove the 2 screws that fix the swing raster motor to the bracket.
10
Remove the swing raster motor.
11
Disconnect the wiring harness from the swing raster motor.