![background image](http://html1.mh-extra.com/html/daikin/perfera-arxm-r-series/perfera-arxm-r-series_service-manual_2460267081.webp)
3
|
Components
Service manual
81
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a
b
a
Expansion valve motor
b
Expansion valve motor harness
7
Cut all tie straps that fix the expansion valve motor harness.
8
Disconnect the expansion valve motor connector S20 from the main PCB.
9
Remove the expansion valve motor (and harness) from the unit.
10
To install the expansion valve motor, see
To remove the expansion valve body
Prerequisite:
Recuperate the refrigerant from the refrigerant circuit, see
209].
Prerequisite:
If needed, remove any parts or insulation to create more space for
the removal.
1
Remove the expansion valve motor, see
79].
2
Remove the putty. Keep for re-use.
a
b
c
a
Putty
b
Expansion valve pipe
c
Expansion valve body