![background image](http://html1.mh-extra.com/html/daikin/perfera-arxm-r-series/perfera-arxm-r-series_service-manual_2460267173.webp)
3
|
Components
Service manual
173
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
b
a
c
d
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
5
Remove the swing flap motor from the coupling piece.
6
To install the swing flap motor, see
172].
To install the swing flap motor
1
Install the coupling piece on the swing flap motor.
2
Install the swing flap motor in the correct location on the indoor unit.
b
a
c
d
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
3
Install and tighten the screw to fix the swing flap motor.
4
Install the swing flap.
5
Install the swing raster motor, see
6
Install the switch box, see
Is the problem solved?
Action
Yes
No further actions required.