![background image](http://html1.mh-extra.com/html/daikin/perfera-arxm-r-series/perfera-arxm-r-series_service-manual_2460267186.webp)
3
|
Components
Service manual
186
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
7
Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
d
c
a
a
b
a
Screw (swing raster motor assembly)
b
Swing raster motor assembly
c
Fan guard
d
Swing raster motor rod
8
Connect the swing raster motor rod to the swing raster shaft using soft tools.
9
Tighten the 2 screws to properly fix the swing raster motor assembly.
10
Install the fan guard.
11
Connect the drain hose to the indoor unit.
a
b
a
Screw (drain hose)
b
Drain hose
12
Install the drain hose fixation bracket. Install and tighten the screw.
13
151].
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.