3
|
Components
Service manual
120
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
INFORMATION
It is recommended to perform the checks in the listed order.
To perform a power check of the intelligent eye sensor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see
151].
2
Turn ON the power of the unit.
3
Remove the control panel from the indoor unit.
4
Measure the power supply voltage between the pins 1‑2 on the intelligent eye
sensor connector CN.
Result:
The measured voltage MUST be 4.75~5.25 V DC.
a
b
a
Control panel
b
Intelligent eye sensor connector CN
Is the measured power supply voltage
correct?
Action
Yes
Perform an electrical check of the
intelligent eye sensor, see
No
Continue with the next step.
5
Measure the output voltage between between the pins 1‑2 on the connector
S602 on the indoor unit main PCB.
Result:
The measured voltage MUST be 4.75~5.25 V DC.
Is the output voltage on the indoor unit
main PCB correct?
Action
Yes
Replace the intelligent eye sensor
wiring harness, see
No
Perform a check of the indoor unit main
PCB, see
To perform an electrical check of the intelligent eye sensor
Prerequisite:
First perform a power check of the intelligent eye sensor, see
119].