![background image](http://html1.mh-extra.com/html/daikin/perfera-arxm-r-series/perfera-arxm-r-series_service-manual_2460267184.webp)
3
|
Components
Service manual
184
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
Class 50~71 indoor unit
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
151].
1
Remove the switch box, see
2
Put a small drain pan (or container) under the drain hose.
3
Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
a
b
a
Screw (drain hose)
b
Drain hose
4
Remove the swing raster motor cover.
e
d
c
a
b
c
a
Swing raster motor cover
b
Swing raster motor assembly
c
Screw (swing raster motor assembly)
d
Fan guard
e
Swing raster motor rod
5
Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
6
Disconnect the swing raster motor rod from the swing raster shaft.
7
Remove the swing raster motor assembly from the indoor unit.
8
Remove the 2 screws that fix the swing raster motor to the bracket.