![background image](http://html1.mh-extra.com/html/daikin/perfera-arxm-r-series/perfera-arxm-r-series_service-manual_2460267060.webp)
3
|
Components
Service manual
60
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
8
Heat the ends of the compressor pipes using an oxygen acetylene torch and
remove the compressor pipe ends.
9
Stop the nitrogen supply when the piping has cooled down.
10
Remove the all the nuts and remove the compressor from the unit.
b
c
a
c
A
A
Class 20~35 unit
a
Nut
b
Compressor
c
Damper
b
a
c
a
c
A
A
Class 42~71 unit
a
Nut
b
Compressor
c
Damper
a
a
b
c
c
c
a
a
Nut
b
Compressor