3
|
Components
Service manual
177
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a
b
c
a
Screw (drain hose)
b
Drain hose
c
Swing raster motor cover
4
Remove the swing raster motor cover.
5
Disconnect the wiring harness from the swing raster motor.
6
Remove the swing flap motor wiring harness.
7
To install the swing flap motor wiring harness, see
199].
To install the swing flap motor wiring harness
1
Connect the wiring harness connector to the swing raster motor.
2
Install the swing raster motor cover.
a
b
c
a
Screw (drain hose)
b
Drain hose
c
Swing raster motor cover
3
Install the drain hose on the indoor unit.
4
Install the drain hose fixation bracket. Install and tighten the screw.
5
Install the swing flap motor, see
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.