![background image](http://html1.mh-extra.com/html/daikin/perfera-arxm-r-series/perfera-arxm-r-series_service-manual_2460267170.webp)
3
|
Components
Service manual
170
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
After complete check of the indoor unit
main PCB, is the problem solved?
Action
No
Replace the streamer unit, see
3.16.2 Repair procedures
To remove the streamer unit
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
151].
1
Disconnect the connector from the streamer unit.
b
a
A
A
Wall mounted indoor unit
a
Streamer unit connector
b
Streamer unit
b
a
A
A
Floor standing indoor unit
a
Streamer unit connector
b
Streamer unit
2
Click the streamer unit out of the indoor unit.
3