background image

 

INSTALLATION MANUAL

 

FDYP125B8V1
FDYP200B8V1
FDYP250B8V1

FDQ125B8V3B
FDQ200B8V3B
FDQ250B8V3B

 

Split System air conditioners

Summary of Contents for FDQ125B8V3B

Page 1: ...INSTALLATION MANUAL FDYP125B8V1 FDYP200B8V1 FDYP250B8V1 FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B Split System air conditioners ...

Page 2: ... 2 2 1 4 5 3 1 2 4 1440 602 125 class 840 200 250 class P1 P2 1 2 3 P2 1 2 3 L N P1 2 3 1 4 5 3 2 6 P1 P2 P1 P2 1 2 3 P2 1 2 3 L N P1 2 3 1 4 5 3 2 6 7 P1 P2 1 2 3 P2 1 2 3 L N P1 1 2 3 P2 1 2 3 L N P1 1 2 3 P2 1 2 3 L N P1 2 3 1 4 5 3 2 6 2 1 1 2 3 4 5 6 7 8 9 ...

Page 3: ... atitinka žemiau nurodytus standartus ir arba kitus norminius dokumentus su sąlyga kad yra naudojami pagal mūsų nurodymus 23 tad ja lietoti atbilstoši ražotāja norādījumiem atbilst sekojošiem standartiem un citiem normatīviem dokumentiem 24 sú v zhode s nasledovnou ými normou ami alebo iným i normatívnym i dokumentom ami za predpokladu že sa používajú v súlade s našim návodom 25 ürünün talimatları...

Page 4: ...maintenance and service can be ensured Refer to figure 1 service space The power supply intake 1 the drain connection 2 gas pipe 3 and liquid pipe 4 connection should always be accessible for maintenance and service Where piping between indoor and outdoor units is possible within the allowable limit Refer to the installation manual for the outdoor unit Where there is no danger of fire due to leaka...

Page 5: ... in places exposed to the air flow from the unit or under the indoor unit It may cause incomplete combustion or deformation of the unit due to the heat Tick when checked Is the indoor unit fixed firmly The unit may fall down vibrate or make noise Is the gas leak test finished It may result in insufficient cooling Is the unit fully insulated Condensate water may drip Does drainage flow smoothly Con...

Page 6: ...cting or disconnecting pipes to from the unit Refer to figure 4 Refer to the table below for the dimensions of flare nut spaces Because R407C R410A refrigerant is used apply ether or ester oil around the flare portions before connecting Coat here with ether oil or ester oil Refer to the table above to determine the proper tightening torque Overtightening may damage the flare and cause leaks Check ...

Page 7: ...e interconnection wiring from outdoor to indoor to the 1 2 3 terminal 1 using a separate power supply of the indoor unit fan motor to the L N terminal Remote controller code Connect the cords to the remote controller terminal P1 P2 No polarity 2 Precautions Do not clamp remote controller cords together with the other wiring Doing so may cause malfunction Do not place the controller where it is exp...

Page 8: ...rotect the unit 1 Open the gas side stop valve 2 Open the liquid side stop valve 3 Electrify crank case heater for 6 hours 4 Set to cooling operation with the remote controller and start operation by pushing ON OFF button 5 Press Inspection Test Operation button 4 times and operate at Test Operation mode for 3 minutes 6 Press Inspection Test Operation button and operate normally 7 Confirm function...

Page 9: ...or Sky Air series only for FDYP125 250 X33A Connector Adaptor for wiring X40A Connector remote on off forced off X60A X61A Connector interface adaptor for Sky Air series only for FDQ Wired remote controller BS1 ON OFF button BS2 Timer mode start stop button BS3 BS8 Programming timer button BS4 Temperature setting button up BS6 Operation mode selector button BS7 Timer on off button BS9 Temperature ...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW23694 1A ...