![Daikin ARK25BVMB Service Manual Download Page 29](http://html.mh-extra.com/html/daikin/ark25bvmb/ark25bvmb_service-manual_501295029.webp)
Specifications
SiBE04-302
20
Specifications
230V, 50Hz
Notes:
MAX. interunit piping length: 15m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units
FTYS20BVMB
FTYS25BVMB
Outdoor Units
RYS20BVMB
RYS20BVMB
Cooling
Heating
Cooling
Heating
Capacity
Rated (Min.~Max.)
kW
2.0
2.6
2.5
3.3
Btu/h
6,850
8,900
8,550
11,300
kcal/h
1,720
2,240
2,150
2,840
Moisture Removal
L/h
0.9
—
1.2
—
Running Current (Rated)
A
3.4
4.1
4.5
5.0
Power Consumption
Rated (Min.~Max.)
W
690
805
890
1,025
Power Factor
%
88.2
85.4
86.0
89.1
COP (Rated)
W/W
2.90
3.23
2.81
3.22
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Units
FTYS20BVMB
FTYS25BVMB
Front Panel Color
White
White
Air Flow Rate
m³/min
(cfm)
H
7.5 (265)
7.6 (265)
7.8 (276)
7.9 (279)
M
5.6 (198)
6.3 (223)
6.0 (212)
6.6 (233)
L
3.9 (138)
5.0 (177)
4.2 (148)
5.3 (187)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
18
18
Speed
Steps
5 Steps and Auto
5 Steps and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.18
0.18
0.18
0.18
Power Consumption (Rated)
W
40
40
40
40
Power Factor
%
96.6
96.6
96.6
96.6
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
273×784×185
273×784×185
Packaged Dimensions (W×D×H)
mm
834×325×258
834×325×258
Weight
kg
7.5
7.5
Gross Weight
kg
11
11
Operation
Sound
H/M/L
dBA
38 / 32 / 26
38 / 32 / 26
39 / 33 / 27
39 / 33 / 27
Sound Power dBA
H
54
—
55
—
Outdoor Units
RYS20BVMB
RYS25BVMB
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
1YC23KXA#A
1YC23KXA#A
Motor Output
W
600
600
Refrigerant
Oil
Type
FVC50K
FVC50K
Charge
L
0.43
0.43
Refrigerant
Type
R410A
R410A
Charge
kg
0.79
0.79
Air Flow Rate
m³/min
29.0
25.5
29.0
25.5
cfm
1,025
901
1,025
901
Fan
Type
Propeller
Propeller
Motor Output
W
25
25
Running Current (Rated)
A
3.22
3.92
4.32
4.82
Power Consumption (Rated)
W
650
765
850
985
Power Factor
%
87.8
84.8
85.5
88.9
Starting Current
A
4.1
5.0
Dimensions (H×W×D)
mm
560×695×265
560×695×265
Packaged Dimensions (W×D×H)
mm
797×310×599
797×310×599
Weight
kg
34
34
Gross Weight
kg
37
37
Operation Sound
dBA
47
48
47
48
Sound Power dBA
H
60
—
60
—
Drawing No.
3D039746A
3D039747A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Summary of Contents for ARK25BVMB
Page 17: ...Functions SiBE04 302 8 List of Function ...
Page 31: ...Specifications SiBE04 302 22 Specifications ...
Page 137: ...Check SiBE04 302 128 Service Diagnosis ...
Page 172: ...SiBE04 302 Outdoor Unit Removal Procedure 163 4 Remove the fan motor Step Procedure Points ...
Page 184: ...SiBE04 302 Others 175 Part 8 Others 1 Others 176 1 1 Explanation 176 1 2 Jumper Settings 177 ...
Page 195: ...Wiring Diagrams SiBE04 302 186 Appendix ...
Page 199: ...SiBE04 302 iv Index ...