Indoor Unit
SiBE04-302
138
Removal Procedure
1.4
Removal of Switch Box, PC Board and Swing Motor
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove front grill.
1. Remove
switch box
.
1
Disconnect the
connection wires.
2
Disconnect connectors
(
S1
and
S7
) of fan
motor.
Pay attention to the direction
of the retainer of the
thermistor so that the
retainer will not touch the
harness (same as the
existing models.)
3
Disconnect one
connector (
S6
) of swing
motor.
4
Remove
heat
exchanger thermistor
.