![Daikin ARK25BVMB Service Manual Download Page 16](http://html.mh-extra.com/html/daikin/ark25bvmb/ark25bvmb_service-manual_501295016.webp)
SiBE04-302
Functions
List of Function
7
Category
Functions
FT
Y
S
20·
25·
35B
V
M
B
RY
S
20·
25
·35B
V
M
B
Category
Functions
FT
Y
S
20·
25·
35B
V
M
B
RY
S
20·
25
·35B
V
M
B
Basic
Function
Inverter (with Inverter Power Control)
—
Health &
Clean
Air Purifying Filter with Bacteriostatic,
Virustatic Functions
{
Operation Limit for Cooling (°C)
10~46
Operation Limit for Heating (°C)
–10~15.5
Photocatalytic Deodorizing Filter
—
PAM Control
—
Air Purifying Filter with Photocatalytic
Deodorizing Function
—
Compressor
Oval Scroll Compressor
—
Longlife Filter
—
Swing Compressor
{
Ultra-Longlife Filter (Option)
—
Rotary Compressor
—
Mold Proof Air Filter
{
Reluctance DC Motor
—
Wipe-clean Flat Panel
{
Comfortable
Airflow
Power-Airflow Flap
—
Washable Grille
—
Power-Airflow Dual Flaps
{
Filter Cleaning Indicator
—
Power-Airflow Diffuser
—
Good-Sleep Cooling Operation
—
Wide-Angle Louvers
{
Timer
24-Hour On/Off Timer
{
Vertical Auto-Swing (Up and Down)
{
Night Set Mode
{
Horizontal Auto-Swing (Right and Left)
—
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
3-D Airflow
—
Self-Diagnosis (Digital, LED) Display
{
★
3-Step Airflow (H/P Only)
—
Wiring Error Check
—
Comfort
Control
Auto Fan Speed
{
Anticorrosion Treatment of Outdoor
Heat Exchanger
{
Indoor Unit Silent Operation
—
Night Quiet Mode (Automatic)
—
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
—
Outdoor Unit Silent Operation (Manual)
—
Intelligent Eye
—
Flexible Voltage Correspondence
{
Quick Warming Function
—
High Ceiling Application
—
Hot-Start Function
—
Chargeless
10m
Automatic Defrosting
—
Power Selection
—
Operation
Automatic Operation
—
Remote
Control
5-Rooms Centralized Controller
(Option)
{
Programme Dry Function
{
Remote Control Adaptor
(Normal Open-Pulse Contact)(Option)
{
Fan Only
{
Lifestyle
Convenience
New Powerful Operation (Non-Inverter)
{
Remote Control Adaptor
(Normal Open Contact)(Option)
{
Inverter Powerful Operation
—
Priority-Room Setting
—
DIII-NET Compatible (Adaptor)(Option)
—
Cooling / Heating Mode Lock
—
Remote
Controller
Wireless
{
Home Leave Operation
—
Wired
—
Indoor Unit On/Off Switch
{
Signal Reception Indicator
{
Temperature Display
—
Another Room Operation
—
Note:
{
: Holding Functions
— : No Functions
★
: Digital Only
Summary of Contents for ARK25BVMB
Page 17: ...Functions SiBE04 302 8 List of Function ...
Page 31: ...Specifications SiBE04 302 22 Specifications ...
Page 137: ...Check SiBE04 302 128 Service Diagnosis ...
Page 172: ...SiBE04 302 Outdoor Unit Removal Procedure 163 4 Remove the fan motor Step Procedure Points ...
Page 184: ...SiBE04 302 Others 175 Part 8 Others 1 Others 176 1 1 Explanation 176 1 2 Jumper Settings 177 ...
Page 195: ...Wiring Diagrams SiBE04 302 186 Appendix ...
Page 199: ...SiBE04 302 iv Index ...