![Daikin ARK25BVMB Service Manual Download Page 162](http://html.mh-extra.com/html/daikin/ark25bvmb/ark25bvmb_service-manual_501295162.webp)
SiBE04-302
Outdoor Unit
Removal Procedure
153
2
The top plate and the
front plate are
constructed in a
monoblock. Remove
the three screws on the
right side and the two
screws on the front
plate.
3
Remove the three
screws on the left side.
4
Remove the one fixed
screw in the rear of the
top plate. Once lift the
top plate and then
remove it forward.
The left side plate and the
bell mouth can be removed
all at once.
When restoring the top plate,
move it horizontally and get
it down for the easy work.
Step
Procedure
Points
Summary of Contents for ARK25BVMB
Page 17: ...Functions SiBE04 302 8 List of Function ...
Page 31: ...Specifications SiBE04 302 22 Specifications ...
Page 137: ...Check SiBE04 302 128 Service Diagnosis ...
Page 172: ...SiBE04 302 Outdoor Unit Removal Procedure 163 4 Remove the fan motor Step Procedure Points ...
Page 184: ...SiBE04 302 Others 175 Part 8 Others 1 Others 176 1 1 Explanation 176 1 2 Jumper Settings 177 ...
Page 195: ...Wiring Diagrams SiBE04 302 186 Appendix ...