9
|
Electrical installation
Installer reference guide
99
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
X1M
OR
1N~
3N~
L1 L2 L3 N
L N
3
If necessary, connect the separate normal kWh rate power supply.
INFORMATION
Some types of preferential kWh rate power supply require a separate normal kWh
rate power supply to the outdoor unit. This is required in the following cases:
▪
if the preferential kWh rate power supply is interrupted when active, OR
▪
if no power consumption of the hydro module of the outdoor unit is allowed at
the preferential kWh rate power supply when active.
N
L
X2M.6
X2M.5
1N~, 50 Hz,
230 V AC, 6.3 A
6
5
X2M
4
Connect the preferential power supply contact.
X5M.10
X5M.9
S1S